CORONA 2.4Ghz 6-Channel PWM/ SBUS Receiver F6D8 (D8 compatible)
    SKU COR-F6D8
    Brand CORONA
    Added 2022/06/15
    Updated 2022/06/15
     
    Tags: CORONA_2.4Ghz_6-Channel_PWM_SBUS_Receiver_F6D8_D8_compatible 

    Features:

    Corona F6D8 D8 Compatible receiver isavailable for any TX that use the Frsky D8 protocol, such as FrSky two waytelemetry modules: DFT, DJT, DHT, XJT, XJT_lite, etc.


    Features:

          Six channels of PWM output for servos.


          One SBUS channel for special usage(connect FC or expand servo channel).


    That canbe set the alarm warning on low voltage and return signal in the TX



    Specifications:

    CORONA 2.4Ghz 6-Channel PWM/ SBUS Receiver F6D8 (D8 compatible)



    Specifications:

    Dimension: 40x18x10mm

    Weight: 5g

    Operating VoltageRange: 3.5V-10.0V

    Operating Current: Max60mA

    Operating Range: Fullrange (max 1.5km)

    Servo Frame Rate:18ms

    SBUS Frame Rate: 9ms


    Bind procedure:

     

    First, turnon the TX and swicth to Bind mode. Second, power on the receiver whileholding the F/S button on the receiver (not connect any servo or other device) and you can see agreen LED going on steady on the receiver. And buzzer begins to sound beebee.The red LED on the receiver will flash, indicating the bind iscompleted. Turn off both the transmitter and the receiver. Turnon the transmitter and power on the receiver. The greenLED that going on steady on the receiver indicates that the receiver isreceiving commands from the transmitter.

     

    Failsafe Setting:

        The compatible receivers support failsafe seton the receiver. Turn on the transmitter and power on the receiver. User canpress and release the F/S button as pictured and all channels data will berecorded by the receiver in the first 30s before receivers and TX are connected.When operating failsafe setting, it is not recommended that servos or otherdevices connect with the receiver. After completing failsafe setting, a stablepower supply to the receiver is recommended.

          Failsafe setting will be cancelled whenresetting the bind procedure

    LED Status Indication

    RED

    GREEN

    Indication

    stable

    off

    No Signal

    off

    stable

    Good Signal

    flash

    stable

    Not Very Good Signal

    flash

    flash

    Poor Signal

    Includes/Requires:

    Includes:
    1 x receiver